Methanometer MTS-3

By In Products @en On 11 May 2014


The Mathanometer MTS-3 type is an electronic device used for the measurement of methane concentration in the air (also ethylene, acetylene and hydrogen).

The Mathanometer MTS-3 type is an electronic device used for the measurement of methane concentration in the air (also ethylene, acetylene, propane and hydrogen). A visual and audible alarm is automatically triggered when exceeding the alarm thresholds (x2). It has a measuring range up to 100% CH4 and can be equipped with either a catalytic or Infra-Red sensor. The MTS-3 can be connected directly to a PC to archive data.

Technical data:

Principle of operation catalytic or Infra-Red sensor
Measuring range 0-100% CH4
Communication with user 3-digital display, 7-segments LED 12mm or LCD
Measuring accuracy 0,1% CH4 in range to 5% CH4, 2% CH4 in range to 100% CH4
Power supply Internal accumulator, operating time in vigil mode approx. 14h (up to 24h with IR sensor)
Alarm signaling acoustic signal and blinking LED display
Ingress protection IP67
Dimensions/Weight 100mm x 65mm x 32mm / 220g
Certyfikat OBAC13ATEX0191X